LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2014 >> Lancer ES Sportback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Electronic Control AWD - With Diagnostics - Lancer RALLIART, Se) >> On-Vehicle Service >> Check Of Electronic Control Coupling >> Resistance Measurement Between Electronic Control Coupling Solenoid Connector Terminals

Resistance Measurement Between Electronic Control Coupling Solenoid Connector Terminals

WARNING: This page is about a different variant/trim than selected.

Disconnect the F-44-1 connector, and measure the resistance value between the connector terminals on the electronic control coupling side. If the measured resistance value is out of the standard value range, replace the electronic control coupling (Refer to ELECTRONIC CONTROL COUPLING  ).

Standard value: 2.2 - 4.0 Ω [at 20 °C (68°F)] 

Fig 1: Measuring Resistance Between Electronic Control Coupling Solenoid Connector Terminals
G08293743