LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2014 >> Lancer ES Sportback >> Repair and Diagnosis >> External Pages >> Different car >> Section 80 (Door System) >> Input Signal Procedures - Central Door Locking System >> INSPECTION PROCEDURE B-1: The Liftgate Lock Release Handle Signal Is Not Received >> Diagnosis

INSPECTION PROCEDURE B-1: The Liftgate Lock Release Handle Signal Is Not Received: Diagnosis

WARNING: This page is about a different car, the 2014 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
  1. STEP 1. liftgate lock release handle check. 

    Check that the liftgate lock release handle is normal (Refer to INSTALLATION SERVICE POINTS < Vehicles without power liftgate >, >> D << STRIKER INSTALLATION < Vehicles with power liftgate >).

    Q: Is the check result normal? 

    • YES:  Go to Step 2.
    • NO:  Replace the liftgate lock release handle.
  2. STEP 2. Resistance measurement at liftgate lock release handle connector (ground line terminal). 
    1. Disconnect the connector, and measure at the wiring harness side.
    2. Measure the resistance between the liftgate lock release handle connector (ground line terminal) and body ground.

      OK: Continuity exists (2 or less) 

    Q: Is the check result normal? 

    • YES:  Go to  Step 4.
    • NO:  Go to Step 3.
  3. STEP 3. Check of open circuit in ground line between liftgate lock release handle connector and body ground. 

    Q: Is the check result normal? 

  4. STEP 4. Check of open circuit in GTOP line between ETACS-ECU connector and liftgate lock release handle connector. 

    Q: Is the check result normal? 

    • YES:  Go to Step 5.
    • NO:  Repair the connector(s) or wiring harness.
  5. STEP 5. Using scan tool (M.U.T.-III), check data list. 

    Check the signals related to the liftgate lock release handle operation.

    CAUTION: To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III).
    1. Connect scan tool (M.U.T.-III). Refer to GROUP 42B, KEYLESS OPERATION SYSTEM (KOS) - WITH DIAGNOSTICS .
    2. Turn the ignition switch to the "ON" position.
    3. Check the data list of the ETACS.
      • Liftgate lock release handle: from OFF to ON
        Item No. Item name Normal condition
        230 Gate opener from OFF to ON
    4. Turn the ignition switch to the "LOCK" (OFF) position.

      OK: Normal condition is displayed. 

    Q: Is the check result normal?