LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2012 >> Lancer SE >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Interior - Lancer >> Seat Assembly >> Inspection >> Seatback Heater Check

Seatback Heater Check

Measure the resistance between terminals.

Standard value: At room temperature 20 °C (68 °F) 

SEATBACK HEATER CONDITIONS

Tester connection Specified condition
terminal 1 - terminal 2 4.86 - 5.94 Ω < Standard seat >
4.06 - 4.96 Ω < Sport seat >
5.40 - 6.60 Ω < RECARO seat >
Fig 1: Measuring Resistance Between Seatback Heater Terminals
G05905558Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.