Daytime Running Light Relay Check
DAYTIME RUNNING LIGHT RELAY CHECK
| Battery voltage |
Terminal number |
Normal conditions |
| Not energized |
3 - 4 |
No continuity |
| With current supply [terminal 1 (+), terminal 2 (-)] |
Continuity exists (2 ohms or less) |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.