LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2010 >> Lancer ES, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 36 (General - Electrical - Lancer Evolution) >> How To Diagnose >> Checking Relays

Checking Relays

WARNING: This page is about a different car, the 2012 Mitsubishi Lancer. However, it is still accessible from the selected car via links, so may be relevant.
  1. By using a relay, a heavy current can be turned on and off by a switch using much less current. For example, in the circuit shown in the illustration, when the switch is turned on (closed), current flows to the coil of the relay. Then, its contact is turned on (closed) and the light comes on. The current flowing through the switch is much less than that for the light.
    Fig 1: Relay Circuit Diagram
    G06676618Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. When current flows through the coil of a relay, its core is magnetized to attract the iron piece, closing (ON) the contact at the tip of the iron piece. When the coil current is turned off, the iron piece returns to its original position by a spring, opening the contact (OFF).
    Fig 2: Normally Open Type - Energized State
    G06676619Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. Relays may be classified as the normally open-type or the normally closed-type, depending on their contact construction.
    NOTE: The deenergized state means that no current is flowing through the coil. The energized state means that current is flowing through the coil.
    1. The normally open-type

      When a normally open relay as illustrated here is checked, there should be no continuity between terminals 3 and 4 when the relay is deenergized. There should be continuity between terminals 3 and 4 when battery voltage and ground are applied to terminals 1 and 2. The relay condition is determined by this check.

      Fig 3: Normally Open Type - Deenergized State/Energized State Current Flows
      G06676620Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
      NOTE: Check the relay in both situation which is energized and is not energized.
    2. The normally closed-type

      When a normally closed relay as illustrated here is checked, there should be continuity between terminals 3 and 4 when the relay is deenergized. There should be no continuity between terminals 3 and 4 when battery voltage and ground are applied to terminals 1 and 2. The relay condition is determined by this check.

      NOTE: Check the relay in both situation which is energized and is not energized.
      Fig 4: Normally Closed Type - Deenergized State/Energized State Current Flow
      G06676621Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.