>>A<< Air Hose/Air Pipe Installation
- Insert hose to stopper end and not overlap with stopper.
- Place the hose clamp as shown in the illustration so that it does not overlap with the bulge and the stopper end. Then, set the hose clamp 5 ± 1 mm (0.20 ± 0.04 inch) away from the stopper.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
CAUTION: Do not use an electric screwdriver or air tool. Manually tighten the hose clamp. - Align the mating marks on the air hose, air pipe, and hose clamp. Then, tighten the hose clamp to the specified torque.
Tightening torque: 6.0 ± 1.0 N.m (54 ± 8 in-lb)