Power Window Switch Continuity Check
Sub switch
TESTER CONNECTION AND SPECIFIED CONDITION CHART
| Switch position |
Tester connection |
Specified condition |
| UP |
4 - 5, 6 - 7 |
Continuity exists (2 Ω or less) |
| OFF |
4 - 5, 7 - 8 |
Continuity exists (2 Ω or less) |
| DOWN |
4 - 6, 7 - 8 |
Continuity exists (2 Ω or less) |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.