Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
- STEP 1. Check other diagnosis codes.
Q: Are other diagnosis codes set?
YES : Go to the appropriate troubleshooting.
NO : Go to Step 2.
- STEP 2. Check the following connector:
- B-125 CVT assembly connector
- C-37 TCM connector
- A-12 Intermediate connector
Check contacts for internal short circuit.
Q: Is the check result normal?
YES : Go to Step 3.
NO : Repair the defective connector.
- STEP 3. Check for short to ground in the wiring harness between the TCM connector and the CVT assembly connector.
- Between C-37 TCM connector (terminal No. 39) and B-125 CVT assembly connector (terminal No. 7)
OK: 100 Ω or more
Q: Is the check result normal?
YES : Go to Step 4.
NO : Repair the wiring harness.
- STEP 4. Symptom recheck after erasing diagnosis code
Q: Is the check result normal?
YES : Intermittent malfunction
NO : Replace the TCM, and then go to Step 5.
- STEP 5. Retest the system.
Q: Is the check result normal?
YES : The inspection is complete.
NO : Replace the CVT assembly.