Descriptions Of Monitor Methods
WARNING: This page is about a different variant/trim than selected.
- The status with the secondary pulley speed of 1,000 r/min or more and with the primary pulley speed of 300 r/min or less continues for five seconds.
- 0.1 second after the primary pulley speed has dropped abruptly from 1,000 r/min or more to 300 r/min or less
- Primary pulley speed sensor is found abnormal by comparing the engine speed with the secondary pulley speed.