Configuration Function
With the scan tool MB991958 operation, the following functions can be programmed. The programmed information is held even when the battery is disconnected.
ADJUSTMENT ITEM CHART
| Adjustment item (scan tool display) | Adjustment item | Adjustment contents (scan tool display) | Adjusting contents |
|---|---|---|---|
| Turn power source | Adjustment of turn-signal light operation condition | ACC or IG1 | Operable with ACC or ON position |
| IG1 | Operable with ON position (default) | ||
| Comfort flasher | With/without comfort flasher function | Disable | Without function |
| Enable | With function (default) | ||
| Comfort flasher switch time | Switch operation time to activate the comfort flasher function | Normal | 0.4 seconds (default) |
| Long | 0.8 seconds | ||
| Hazard answer back | Adjustment of the number of keyless hazard warning light answer back flashes | Lock:1, Unlock:2 | LOCK: Flashes once, UNLOCK: Flashes twice (default) |
| Lock:1, Unlock:0 | LOCK: Flashes once, UNLOCK: No flash | ||
| Lock:0, Unlock:2 | LOCK: No flash, UNLOCK: Flash twice | ||
| Lock:2, Unlock:1 | LOCK: Flash twice, UNLOCK: Flash once | ||
| Lock:2, Unlock:0 | LOCK: Flash twice, UNLOCK: No flash | ||
| Lock:0, Unlock:1 | LOCK: No flash, UNLOCK: Flash once | ||
| Lock:0, Unlock:0 | Without function | ||
| Headlight auto cut customize | Adjustment of headlight automatic shutdown function | Disable | Without function |
| Enable (C-spec). | With function (default) |