Inspection Procedure 2: During the conversation with the hands-free system, the speaker's voice cannot be heard by the other party: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- STEP 1. Check the cellular phone.
Check that the cellular phone can be used normally as a unit.
Q: Is it possible to use the cellular phone normally?
YES: Go to Step 2.
NO: Repair or replace the cellular phone.
- STEP 2. Check hands-free module connector C-121 and microphone unit connector D-01 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Are hands-free module connector C-121 and microphone unit connector D-01 in good condition?
YES: Go to Step 3.
NO: Repair or replace the damaged component(s). Refer to HARNESS CONNECTOR INSPECTION .
- STEP 3. Check the wiring harness between hands-free module connector C-121 and microphone unit connector D-01.
- Disconnect hands-free module connector C-121 and microphone unit connector D-01, and check the wiring harness.NOTE: Also check intermediate connector C-36 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If intermediate connector C-36 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
- Check the wiring harness between hands-free module connector C-121 (terminal No.1) and microphone unit connector D-01 (terminal No.22)
- Check the wiring harness between hands-free module connector C-121 (terminal No.1) and microphone unit connector D-01 (terminal No.23)
- Check the wiring harness between hands-free module connector C-121 (terminal No.2) and microphone unit connector D-01 (terminal No.24)
Q: Is the wiring harness between hands-free module connector C-121 and microphone unit connector D-01 in good condition?
YES: Go to Step 4.
NO: The wiring harness may be damaged or the connector (s) may have loose, corroded or damaged terminals, or terminals pushed back in the connector. Repair the wiring harness as necessary.
- Disconnect hands-free module connector C-121 and microphone unit connector D-01, and check the wiring harness.
- STEP 4. Temporarily replace the microphone unit, and check the trouble symptom.
Check that the normal conversation is possible with the hands free system.
Q: Is the normal conversation possible with the hands-free system?
YES: Replace the microphone unit.
NO: Replace the hands-free module.