LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2007 >> Galant DE >> Repair and Diagnosis >> Accessories & Equipment >> Steering Column Switches >> Chassis Electrical >> Battery >> On-Vehicle Service >> Battery Check >> Battery Visual Inspection (1)

Battery Visual Inspection (1)

  1. Ensure that the battery electrolyte level is between A and B shown in the figure. Add if the level is lower than the specified range.
  2. Use a hydrometer and temperature gauge to check the specific gravity of the electrolyte.

    Standard value: 1.220 - 1.290 [ at 20°C (68°F)] 

The specific gravity of electrolyte depends on its temperature. Use the formula below to determine the proper value.

Fig 1: Checking Specific Gravity Of Electrolyte
G05104983Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

Conversion on centigrade 

20  =(t - 20) x 0.0007 + Dt 

Conversion on Fahrenheit 

20  =(t - 68) x 0.0007 + Dt 

D20 : Specific gravity as if electrolyte temperature is 20°C (68°F)

Dt : Measured specific gravity

t : Measured temperature