INSPECTION PROCEDURE 5: Combination meter does not work: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- STEP 1. Measure at combination meter connector C-04 by backprobing in order to check the battery circuit of power supply system to the combination meter.
- Measure at combination meter connector C-04 without disconnecting the connector.
- Measure the voltage between terminal 35 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
- YES: Go to Step 4) .
- NO: Go to Step 2.
- STEP 2. Check combination meter connector C-04 for damage.
Q: Is combination meter connector C-04 in good condition?
- YES: Go to Step 3.
- NO: Repair or replace the connector. Check to see that all meters operate.
- STEP 3. Check the wiring harness between combination meter connector C-04 (terminal 35) and fusible link (1). NOTE: Also check intermediate connector C-116, junction connectors C-202 and C-204 and joint connector C-02. If intermediate connectors C-116, junction connectors C-202 or C-204 or joint connector C-02 are damaged, repair or replace the connector .
Q: Are the wiring harness between combination meter connector C-04 (terminal 35) and fusible link (1) in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 4. Measure at combination meter connector C-04 by backprobing in order to check the battery circuit of power supply system to the combination meter.
- Measure at combination meter connector C-04 without disconnecting the connector.
- Turn the ignition switch to "ON" position.
- Measure the voltage between terminal 42 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
- YES: Go to Step 7) .
- NO: Go to Step 5.
- STEP 5. Check combination meter connector C-04 for damage.
Q: Is combination meter connector C-04 in good condition?
- YES: Go to Step 6.
- NO: Repair or replace the connector. . Check to see that all meters operate.
- STEP 6. Check the wiring harness between combination meter connector C-04 (terminal 42) and ignition switch (IG1). NOTE: Also check junction connectors C-203 and C-205. If junction connectors C-203 or C-205 are damaged, repair or replace the connector as described in GROUP 00E, Harness Connector Inspection .
Q: Are the wiring harness between combination meter connector C-04 (terminal 42) and ignition switch (IG1) in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 7. Measure at combination meter connector C-04 by backprobing in order to check the ground circuit to the combination meter.
- Measure at combination meter connector C-04 without disconnecting the connector.
- Measure the resistance between terminal 40 and ground.
- The measured value should be 2 ohms or less.
- Measure the resistance between terminal 41 and ground.
- The measured value should be 2 ohms or less.
Q: Does the measured voltage correspond with this range?
- YES: Repair the combination meter. Check to see that all meters operate.
- NO: Go to Step 8.
- STEP 8. Check combination meter connector C-04 for damage.
Q: Is combination meter connector C-04 in good condition?
- YES: Go to Step 9.
- NO: Repair or replace the connector. . Check to see that all meters operate.
- STEP 9. Check the wiring harness between combination meter connector C-04 (terminal 40 and 41) and ground.
Q: Are the wiring harness between combination meter connector C-04 (terminal 40 and 41) and ground in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.