Pattern Select Switch
Disconnect pattern select switch connector. See Fig 1 . Check for continuity between pattern select switch terminals No. 1 and 2. Ensure continuity is present with pattern select switch pressed. Check for continuity between pattern select switch terminals No. 1 and 4. Ensure continuity is present with pattern select switch released. Replace pattern select switch if continuity is not as specified.