Circuit Test
- Disconnect instrument cluster harness connector. Check voltage between ground and instrument cluster harness-side connector terminal No. 33 (White wire). See WIRING DIAGRAMS . Voltmeter should read 5 volts. If voltage is as specified, go to next step. If voltage is not as specified, go to step 4 .
- Check continuity between ground and instrument cluster harness-side connector terminal No. 34 (Black wire). Refer to the WIRING DIAGRAMS . If continuity is present, go to next step. If continuity is not present, go to step 5 .
- Check voltage between ground and instrument cluster harness-side connector terminal No. 42 (Black/White wire). Refer to the WIRING DIAGRAMS . Battery voltage should be present. If battery voltage is present, replace tachometer. If battery voltage is not present, go to step 6 .
- Check harness connectors to ECM, instrument cluster or distributor assembly. Repair as necessary. If connectors are okay, check circuit between ECM, instrument cluster and distributor. See WIRING DIAGRAMS . Repair as necessary.
- Check joint connector to instrument cluster. Repair as necessary. If connector is okay, check circuit between instrument cluster and ground. See WIRING DIAGRAMS . Repair as necessary.
- Check harness and joint connectors to power supply junction block. Repair as necessary. If connectors are okay, check circuit between instrument cluster and power supply. See WIRING DIAGRAMS . Repair as necessary.