Hazard Light Switch Test: Galant
Remove hazard light switch from instrument panel. Disconnect switch connector. Using an ohmmeter, check switch continuity. With switch in OFF position, continuity should exist between terminals No. 3 and 4. With switch in ON position, continuity should exist between terminals No. 1 and 2, between terminals No. 3 and 4. See Figure. If continuity is not as specified, replace hazard light switch.