FOGLIGHT Switch Test: Mirage
Remove foglight switch from instrument panel. Disconnect switch connector. Using an ohmmeter, check switch continuity. With switch in OFF position, continuity should exist between terminals No. 1 and 2. With switch in ON position, continuity should exist between terminals No. 1 and 2, terminals No. 3 and 4, and terminals No. 5 and 6. See Figure. If continuity is not as specified, replace foglight switch.