Fastening the potential equalization line onto the body (right)
- Position the equipotential bonding line (2) on the body.WARNING: Potential equalization in high-voltage system.
Mortal hazard if the potential equalization screw connection is not correct!- Observe the safety requirements for the potential equalization screw connection.
- Clean contact faces and have then checked by a second person.
- Tighten the screws/nuts for potential equalization with torque; have a second person check the torque.
- Correct execution of these tasks must be documented in the vehicle records by both persons.
- Tighten nut (1).TIGHTENING TORQUES SPECIFICATION
Potential equalization line to body M6 8 Nm