Home >> Mini >> 2019 >> Cooper S, 4D Hatchback, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (General Electrical System - Repair (F56) -- Cooper, F56) >> Plug Connections, Terminals >> 61 13... Notes for opening contacts and locks of different plug contact systems >> 61 13... Socket housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo Power

61 13... Socket housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo Power

WARNING: This page is about a different variant/trim than selected.

Manufactured by AMP:  The following bushing housing types without single conductor seal can be fitted into the socket housings:

Manufactured by Siemens:  The following bushing housing types without single conductor seal can be fitted into the socket housings:

Raise lock (1) on housing (2).

Push contact carrier (3) from rear out of housing.

NOTE: The second contact carrier is pushed out in the same way.
Fig 1: Pushing Contact Carrier From Rear Out Of Housing
G11774951Courtesy of BMW OF NORTH AMERICA, INC.

Pushing out the contact carrier releases the secondary locks of the socket contacts.

Hold down snap-in hooks (1) of contact bushing in opening of contact carrier with a small screwdriver.

Pull wire with contact bushing in arrow direction as far as secondary lock (2).

Fig 2: Holding Down Snap-In Hooks Of Contact Bushing In Opening Of Contact Carrier
G11774952Courtesy of BMW OF NORTH AMERICA, INC.

Hold down snap-in hooks in secondary lock (1) again and pull cable with contact bushing (2) completely out of contact carrier (3).

Fig 3: Holding Down Snap-In Hooks In Secondary Lock
G11774953Courtesy of BMW OF NORTH AMERICA, INC.