Home >> Mini >> 2019 >> Cooper S, 4D Hatchback, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (General Electrical System - Repair (F56) -- Cooper, F56) >> Plug Connections, Terminals >> 61 13... Notes for opening contacts and locks of different plug contact systems >> 61 13... In-line plugs, 6- to 50-pin, System Elo

61 13... In-line plugs, 6- to 50-pin, System Elo

WARNING: This page is about a different variant/trim than selected.

Open lock.

Fig 1: Opening Lock
G11774919Courtesy of BMW OF NORTH AMERICA, INC.

Detach cable tie.

Installation note: 

Cable tie must be reinstalled.

Fig 2: Locating Cable Tie
G11774920Courtesy of BMW OF NORTH AMERICA, INC.

Detach catch (1) from connector housing (2).

Fig 3: Detaching Catch From Connector Housing
G11774921Courtesy of BMW OF NORTH AMERICA, INC.

Press out contact carrier (3) with wiring harness (4) through opening (5).

Fig 4: Pressing Out Contact Carrier With Wiring Harness Through Opening
G11774922Courtesy of BMW OF NORTH AMERICA, INC.

Hold down safety catch (6) of defective contact and pull cable and contact up to secondary lock (8).

Fig 5: Holding Down Safety Catch Of Defective Contact
G11774923Courtesy of BMW OF NORTH AMERICA, INC.

Hold down safety catch once again in secondary lock (8) and pull cable and contact completely out of contact carrier.

Fig 6: Holding Down Safety Catch In Secondary Lock
G11774924Courtesy of BMW OF NORTH AMERICA, INC.