Replacing controller for heating and air conditioning system blower
Preliminary work needed:
- Disconnect NEGATIVE BATTERY CABLE .
Removal:
NOTE:
The controller for the blower is located in the footwell on the left behind the heating and air-conditioning unit.
On version with air duct:
Unscrew the screws (1).
Feed out air duct (2).
Unscrew the screws (1).
Unlock plug connections (2) and disconnect.
Remove controller (3).
Installation:
Position controller (3) correctly.
Tighten down screws (1).
Join and lock plug connections (2).
On version with air duct:
Feed in air duct (2).
Tighten down screws (1).
Required follow-up work:
- Connect NEGATIVE BATTERY CABLE .