34 52 516 Removing and installing/replacing DSC control unit
Necessary preliminary tasks:
- Remove HYDRAULIC UNIT .
Removal:
Release screws (1) and remove holder (2).
Release screws (1) and carefully detach control unit (2) towards front.
Preparation for installation:
Cleaning with compressed air, chemical solvents and sharp-edged objects is not permitted.
Do not touch pressure sensor contacts (2) with your fingers or clean the contacts.
If necessary, clean sealing surface (1) with a plastic scraper or a fluff-free cloth.
Check gasket (2) for damage. If damaged, replace DSC control unit (3).
Installation:
Installation note:
Make sure screws are inserted evenly and DSC control unit rests on hydraulic unit.
Replace screws.
Observe tightening sequence (1-3).
Tightening torque 34 51 1AZ .
Attach holder (2).
Insert screws (1) and tighten.
Tightening torque 34 51 2AZ .
Replacement:
Carry out PROGRAMMING/ENCODING .