(Instructions for opening and part exchange in refrigerant circuit)
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2019 MINI Cooper, 2018 MINI Cooper, 2017 MINI Cooper, 2016 MINI Cooper, and 2015 MINI Cooper. However, it is still accessible from the selected car via links, so may be relevant.
Special tools required:
WARNING:
- Follow safety instructions for handling REFRIGERANT and REFRIGERANT OIL .
Attention!
- Always use new O-rings each time A/C connections are opened
- They must not
be coated.
Use special tool 00 9 030 to install sealing rings without damaging them.
- Open the referigerant circuit for as short of a period as possible.
- Close all components and lines in the refrigerant circuit and return parts immediately following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
- If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 h, the dryer insert for the air conditioning must be replaced.
I. Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage.
(minor leak, e.g. hairline crack)
Procedure:
- DRAW OFF heating and air conditioning system, then determine suctioned refrigerant oil level
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 10 ml
- Air conditioning condenser: 20 ml
- Desiccant insert/dryer flask: 20 ml
- Each replaced refrigerant line: 10 ml
- Air conditioning condenser with integrated dryer flask: 40 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- EVACUATE AND FILL air conditioning system
II. Part replacement due to sudden leakage
(major leak, e.g. pipe break due to accident)
Procedure:
- DRAW OFF heating and air conditioning system, then determine suctioned refrigerant oil level
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 35 ml
- Air conditioning condenser: 35 ml
- Desiccant insert/dryer flask: 55 ml
- Each replaced refrigerant line: 35 ml
- Air conditioning condenser with integrated dryer flask: 55 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- EVACUATE AND FILL A/C system