Cleaning evaporator
Special tools required:
- 2 413 653
Wear protective rubber gloves and protective goggles.
If cleaning agent comes into contact with eyes or skin, wash immediately with lots of water.
for handling cleaning agents
Recycling:
Carry out the cleaning operation in a suitable washing bay as the emerging cleaning agent leaks through the drain openings in the transmission tunnel.
Preliminary work needed:
To avoid dirtying vehicle interior:
- Close all the ventilation outlets
- Set air conditioning to recirculated-air mode
- Cover carpet in work area
- F39, F4x, F5x: Remove underbody protection
- I01: Remove the thrust field
- All Vehicles: Remove MICROFILTER for passenger compartment ventilation.
Open flap (1).
Insert special tool 2 413 653 into the microfilter housing (2) as shown.
Position special tool 2 413 653 up against the top right limit position as shown.
Shift special tool 2 413 653 from right to left (1) to the stop.
Shift special tool 2 413 653 back and forth until the A/C system cleaner has been completely sprayed.
After termination of the cleaning operation:
- Let the vehicle drip off for about 5 minutes.
- All vehicles: Install MICROFILTER for the interior ventilation.
- Set air conditioning to footwell ventilation and fresh air mode. Open side windows/doors.
- Start the vehicle and let the air conditioning run for approx. 5 minutes at maximum blower output.
- F39, F4x, F5x: Install underbody protection.
I01: Install thrust field.
- In order to eliminate last remnants of cleaning agent, repeat steps 3 and 4 before handover to the customer.