Removing and installing/replacing fan cowl with electric fan (Cooper)

WARNING: Risk of burning!

Only perform this repair work after engine has cooled down.

When the engine is stopped after the completion of trip, it may be necessary to run the electric fan. In rare cases, operation of the electric fan can last up to 11 min. This protects the components. In this case, replacing the electric fan will not remedy the problem!

Preliminary work needed: 

Removal: 

Remove seal (1) from radiator.

G11645910Courtesy of BMW OF NORTH AMERICA, INC.

Unlock and detach connector (1) from fan cowl.

Unclip clips (2) from fan cowl and place cable to one side.

Unclip coolant hose and tank vent line from fan cowl (3).

G11645911Courtesy of BMW OF NORTH AMERICA, INC.

Unscrew the screws (1).

G11645912Courtesy of BMW OF NORTH AMERICA, INC.

Unlock right lock (1) on fan cowl.

G11645913Courtesy of BMW OF NORTH AMERICA, INC.

Unlock left lock (1) on fan cowl.

G11645914Courtesy of BMW OF NORTH AMERICA, INC.

Feed out fan cowl (1) in arrow direction and remove.

G11645915Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

Feed in fan cowl (1) in arrow direction and install.

G11645916Courtesy of BMW OF NORTH AMERICA, INC.

Lock left and right locks.

G11645917Courtesy of BMW OF NORTH AMERICA, INC.

Tighten down screws (1).

Tightening torque 17 10 1AZ .

G11645912Courtesy of BMW OF NORTH AMERICA, INC.

Connect connector (1) to fan cowl.

Connector (1) must engage audibly.

Connect clips (2) to fan cowl.

Connect coolant hose and venting line (3) to fan cowl.

G11645911Courtesy of BMW OF NORTH AMERICA, INC.

Install seal (1) on radiator.

G11645910Courtesy of BMW OF NORTH AMERICA, INC.

Required follow-up work: