Instructions for opening and part exchange in refrigerant circuit
Special tools required:
- 00 9 030
- 32 1 270
WARNING:
- Avoid contact with refrigerant and refrigerant oil
- Follow SAFETY INSTRUCTIONS for handling R134a refrigerant.
- Follow SAFETY INSTRUCTIONS for handling refrigerant oil.
Attention!
- Always use new O-rings each time A/C connections are opened (see: the applicable BMW Parts Catalog)
They must not be coated.
Use special tool 00 9 030 to install sealing rings without damaging them.
- Open the referigerant circuit for as short of a period as possible.
- Close all components and lines in the refrigerant circuit and return parts immediately following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
- If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 h, the dryer insert for the air conditioning must be replaced.
- Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage.
(minor leak, e.g. hairline crack)
Procedure:
- Suction heating and air conditioning system, then determine suctioned coolant oil level. Refer to: SUCTION, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R134A) or SUCTIONING, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R1234YF)
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES on compressor replacement.
- Evaporator: 10 ml
- Air conditioning condenser: 20 ml
- Desiccant insert/dryer flask: 20 ml
- Each replaced refrigerant line: 10 ml
- Air conditioning condenser with integrated dryer flask: 40 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- Only I01: Radiator, high-voltage battery unit: 20 ml
- Evacuate and fill air conditioning system. Refer to: SUCTION, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R134A) or SUCTIONING, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R1234YF) .
- Part replacement due to sudden leakage
(major leak, e.g. pipe break due to accident)
Procedure:
- Suction heating and air conditioning system, then determine suctioned coolant oil level. Refer to: SUCTION, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R134A) or SUCTIONING, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R1234YF)
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES on compressor replacement.
- Evaporator: 35 ml
- Air conditioning condenser: 35 ml
- Desiccant insert/dryer flask: 55 ml
- Each replaced refrigerant line: 35 ml
- Air conditioning condenser with integrated dryer flask: 55 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- Only I01: Radiator, high-voltage battery unit: 35 ml
- Evacuate and fill A/C system. Refer to: SUCTION, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R134A) or SUCTIONING, EVACUATING AND FILLING HEATING AND AIR CONDITIONING SYSTEM (R1234YF) .