12 14 521 Replacing crankshaft pulse sensor (B36, B38, B46, B48)
IMPORTANT:
Read and comply with notes on PROTECTION AGAINST ELECTROSTATIC DISCHARGE (ESD PROTECTION)
.
Necessary preliminary tasks:
- Remove FAN COWL .
Removal:
Unlock plug (2) from pulse generator and detach.
Release screw (1).
Remove pulse generator (3).
Installation:
Install pulse sensor (3).
Tighten screw (1).
Tightening torque 13 62 2AZ .
Attach connector (2) on pulse sensor.