51 48... Notes for bonding sound insulation (SI), doors
Special tools required:
General:
Sound insulation is bonded to the inner door panel.
Bonded sound insulation must not be subjected to load (e.g. leak test) before 5 hours have elapsed.
On-the-job safety:
When working with bonding products (adhesive, cleaning agent, etc.):
- Wear safety goggles, protective gloves and if necessary an apron.
- Ensure the area is well ventilated.
- Change work clothing contaminated with adhesive immediately.
- Change work clothing contaminated with solvents and swelling agents immediately (keep spare work clothing on hand).
- Take skin protection measures, provide washing facilities including hot water, use silicone-free skin creams.
- Always keep an eye douche on hand, change the water regularly (once a month).
- Comply with the relevant safety regulations.
Handling adhesive area on inner door panel:
| Adhesive | Cleaning |
|---|---|
|
|
Repair in area of sound insulation, door:
| Repair in the event of damaged sound insulation or leakage |
|
The sound insulation must be bonded watertight below the door lock:
- Flat bonding surface required all round.
- No bonding in the event of moisture (e.g. condensation, etc.).
- Bonding area must not show any traces of adhesion-reducing residues (e.g. separating agents, greases, oils, paraffins, plastisols, cavity wax, polishing dust residues, etc.).
- Remove the protective film directly before joining (under no circumstances remove earlier, since the butyl, because of its stickiness, will very quickly pick up adhesion-reducing dirt contaminants).
- The sound insulation must be attached with positional accuracy to the inner door panel because it will no longer be possible to change the position without damaging the butyl bead.
- With repainted areas, the maximum permitted temperature of 90°C may not be exceeded in the area of the sound insulation. Otherwise, the sound insulation must be removed (and replaced, if necessary).
Expiry date of adhesive:
24 months, see label on packaging.
Disposal of the cleaning cloth:
Cleaning cloths and cleaning agent residues are hazardous waste (see also manufacturer's safety data sheet (MSDS)).
Disposal of adhesive:
Hazardous waste (see also manufacturer's safety data sheet (MSDS)).