11 78 610 Removing and installing/replacing monitoring sensor (B36A/B38A)
Special tools required:
Only perform these tasks after exhaust system has cooled down.
Necessary preliminary tasks:
- Remove CLEAN AIR PIPE
Removal:
Unclip connector (1) of monitoring sensor from holder.
Unlock connector (1) of monitoring sensor and disconnect.
Release cable of monitoring sensor from bracket (1).
Release monitoring sensor (1) with special tool 11 7 020 .
Installation:
Installation note:
If an oxygen sensor is reused, thinly and evenly coat only the thread with NEVER-SEEZ COMPOUND (4.3) .
The part of the oxygen control sensor which projects into the exhaust branch (sensor ceramic) must not be cleaned or come into contact with lubricant.
Screw in monitoring sensor (1) and tighten down with special tool 11 7 020 .
Tightening torque: 11 78 1AZ .
Clip monitoring sensor cable in the bracket (1).
Connect the connector (1) of monitoring sensor and clip it into the holder.
Required follow-up work:
- Check function of DME.