41 11 141 Replacing cover for left or right side member
WARNING: This page is about a different variant/trim than selected.
Read contents of BODY, GENERAL .
Following new body parts are required:
- (1) Entrance, outer
IMPORTANT:
Cut through outer plate only for following severance cuts.
Mark severance cuts in accordance with specified dimensions and cut.
Dimension a = approx.45 mm in front of
12x18 mm dia. elongated hole.
Dimension b = approx. 30 mm before 12 mm dia. bore hole.
Open welding spots in areas (1).
Installation note:
Weld in REINFORCEMENT PLATES at all severance cuts.