61 20 503 Vehicle battery - closed-circuit current monitoring
Necessary preliminary tasks:
IMPORTANT:
Do not disconnect negative lead of battery.
To access the ground cable of the battery, perform the necessary preliminary work described in DISCONNECTING BATTERY EARTH LEAD .
Connect appropriate scan tool.
Connect clip-on probe to negative lead of battery. The arrow on the current clamp must point towards the battery.
Measure closed-circuit current.