Home >> Mini >> 2012 >> Cooper Base, 2D Convertible, Automatic Trans >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Gauges & Instrument Panels >> Engine Electrical System - Repair -- R57 >> Starter Lead >> 12 42 500 Replacing battery positive lead (between starter, alternator and battery positive terminal)

12 42 500 Replacing battery positive lead (between starter, alternator and battery positive terminal)

Necessary preliminary tasks: 

Release clamps (1) and detach air intake hose (2).

Fig 1: Identifying Air Intake Hose And Clamps
G04790022Courtesy of BMW OF NORTH AMERICA, INC.

Unlock plug (1) and remove.

Release nut and disconnect battery positive lead (2).

Tightening torque 12 41 2AZ .

Fig 2: Identifying Battery Positive Lead, Plug, And Nut
G04796451Courtesy of BMW OF NORTH AMERICA, INC.

Release screw and remove holder (1).

Fig 3: Identifying Screw And Holder
G04790017Courtesy of BMW OF NORTH AMERICA, INC.

Unlock plug (1) and remove.

Release nut and disconnect battery positive lead (2).

Tightening torque 12 31 2AZ .

Fig 4: Identifying Battery Positive Lead, Plug, And Nut
G04796452Courtesy of BMW OF NORTH AMERICA, INC.

Release bolts.

Tightening torque 12 51 3AZ .

Feed out air wiring harness (1) and remove.

Fig 5: Identifying Air Wiring Harness And Bolts
G04796453Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Check stored fault messages.
Now clear the fault memory.