34 52 535 Replacing a rear pulse generator
WARNING: This page is about a different variant/trim than selected.
Necessary preliminary tasks:
- Partially detach REAR UNDERBODY PANELLING .
Release cable from retaining clip on rear axle carrier (1).
Disengage cable from holder (1) at shock absorber.
Release screw (2) and remove pulse generator (3).
Installation:
Tightening torque 34 51 4AZ
Clean bore hole for pulse generator and grease with Staburags NBU 12/K lubricating grease.
Unclip cable from retainers (1).
Disconnect plug connection (2).
Installation:
Make sure plug connection engages correctly.