LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 39 (Heating And Air Conditioning - Repair - Clubman (R55)) >> Air Conditioning, Leak Detection >> 64 50 010 Drawing Off, Evacuating And Filling A/C System (R134a) >> Notes

64 50 010 Drawing Off, Evacuating And Filling A/C System (R134a): Notes

WARNING: This page is about a different variant/trim than selected.
WARNING:

Refrigerant circuit is under high  pressure!

Repair work may only be carried out on a depressurized  refrigerant circuit!

Before conducting repairs, check the actual pressure drop on the pressure gauge of the A/C service station.

Avoid contact with refrigerant and refrigerant oil.

Follow instructions for handling R134a refrigerant: see 64 50... Safety instructions for handling refrigerant R134a .

Follow 64 50... Safety instructions for handling refrigerant oil .

IMPORTANT:

The suction-side filling line of the refrigerant circuit is omitted from the engine versions of model series E9X and E8X.

This is replaced by a direction connection on the expansion valve.

Changeover time frame:

  • From 07/09 - N54
  • From 08/09 - N43
  • Until end of 2009 - all other engine versions except N45/N46 and S65

Shown on N54 engine by way of example.

Direct connection of filling adapter (1) on the expansion valve is shown.

NOTE: Make sure filling hose (1) is laid without kinks.
Fig 1: Identifying Filler Connection Line
G06851977Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT:

Risk of damage!

Only BMW-approved R134a refrigerant may be used (refer to HEATING AND AIR CONDITIONING -- OPERATING FLUIDS ).

Restart engine only when A/C system has been correctly filled.

IMPORTANT: Risk of damage!
Carefully move the climate service station!
Comply with the operating instructions and service interval for the A/C service station!
Make sure that the hoses of the A/C service station are drained after the drawing off or filling procedure!
The climate service station contains highly sensitive components, such as scales. These components will be damaged due to improper handling, such as fast driving over a bump. This will result in a significant reduction of the measuring accuracy when drawing off and filling.
Fig 2: Evacuating And Filling Heating And Air Conditioning System
G08473976Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: The vehicle must be parked on the ground during all draw-off, evacuation and filling procedures!
Filling a raised vehicle will result in insufficient filling levels.
NOTE: In case of complaints, carry out a heating and air conditioning performance test!
If the system fails the test, draw off, evacuate and fill the heating and air conditioning system in accordance with the operating instructions of the relevant service station.

Instructions for drawing off heating and air conditioning system: 

To help separation of refrigerant and refrigerant oil, run engine at low speed (800-1200 RPM) and with heating and air conditioning system turned on for a few minutes.

The limits the entrainment of refrigerant oil while it is drawn off.

Drawn-off refrigerant oil must be changed and reintroduced via the A/C service station.

During drawing off, set blower of heating and air-conditioning unit to middle blower speed. This ensures that drawing off is more effective since the pressure on the low pressure side increases.

Recycling:

Dispose of drawn-off refrigerant oil as hazardous waste.

Observe country-specific waste disposal regulations.

Instructions for evacuating heating and air conditioning system: 

Before each filling, evacuate the refrigerant system.

Observe an evacuation time of at least 30 minutes  .

The evacuation procedure removes all traces o ambient air, water vapor and any other gases present from the heating and air conditioning system. This enables subsequent system filling with refrigerant.

If the vacuum does not remain stable when the system is off, run the procedure for leaks in the refrigerant circuit.

During evacuation, set blower of heating and a conditioning unit to middle blower speed. This ensures that evacuation is more effective since the pressure on the low pressure side increases.

Instructions for filling heating and air conditioning system: 

Before filling with refrigerant, replace the refrigerant oil entrained during drawing off.

Also top up any lost fluid as indicated in the table:

Loss of R134a refrigerant 

Table 1  indicates the permitted loss of refrigerant after a specific period of time. There is no leak. refrigerant oil may not be topped up.

Table 2  indicates the amount of refrigerant oil must be topped up with an unapproved loss of refrigerant due to a leak after a specific period time.

Different cases: 

  1. Loss of refrigerant per REFRIGERANT OIL LOSS is not exceeded 
    • Top up lost R134a refrigerant
    • It is not permitted  to top up the refrigerant oil
  2. Loss of refrigerant per REFRIGERANT OIL LOSS  is exceeded
    • Top up lost R134a refrigerant
    • refrigerant oil must be topped up additionally  per REFRIGERANT OIL LOSS 
REFRIGERANT OIL LOSS

Number of years since last filling 0 - 1 1 - 2 2 - 3 3 - 4 4 - 5
Permissible loss [g] --> no need to top up refrigerant oil ≤ 30 ≤ 60 ≤ 90 ≤ 120 ≤ 150
REFRIGERANT OIL LOSS

Number of years since last filling R134a loss of coolant [g] Top up quantity refrigerant oil
0 - 1 - <120 0
120 - 150 10
>150 20
1 - 2 - <180 0
180 - 210 10
>210 20
2 - 3 - <240 0
240 - 270 10
>270 20
3 - 4 - <300 0
300 - 330 10
>330 20
4 - 5 - <360 10
>360 20

Follow INSTRUCTIONS  for opening and replacing parts in refrigerant circuit.

Depending on the type of component replaced on the heating and air conditioning system, it may be necessary to the top up the refrigerant oil, even if no measurable losses have occurred during drawing off. Follow the notes provided by the heating and air conditioning system manufacturer, taking account of the tolerances (and inaccuracies) indicated in the operating instructions of the relevant service station.

Information on the required refrigerant fill quantity for the entire heating and air conditioning system is contained on the type plate (1) in the engine compartment.

Fig 3: Identifying Engine Compartment Plate
G04727875Courtesy of BMW OF NORTH AMERICA, INC.

If necessary, refer to TECHNICAL DATA for capacity. See.