11 78 510 Removing and installing/replacing lambda control sensors (N12)
WARNING: This page is about a different variant/trim than selected.
WARNING:
Scalding hazard!
Only perform these tasks after the exhaust system has cooled down.
Only perform these tasks after the exhaust system has cooled down.
Necessary preliminary tasks:
- Read fault memory.
Installation:
If an oxygen sensor is to be reused, only apply a thin and uniform coat of Never Seez Compound to thread.
The part of the oxygen control sensor which projects into the exhaust system branch (sensor ceramic) must not be cleaned or come into contact with lubricant.
Disconnect plug connection for lambda control sensor.
Release oxygen sensor (1) with special tool 11 7 020 .
Tightening torque: 11 78 1AZ .
Assemble engine.
Check function of DME.