64 53 515 Replacing desiccant insert for air conditioning system
WARNING: This page is about a different variant/trim than selected.
Notes
WARNING:
Danger of injury!
Refrigerant circuit is under high pressure!
Follow instructions for handling R 134a refrigerant. See 6450... SAFETY INSTRUCTIONS FOR HANDLING R134A REFRIGERANT or 6450... Instructions for handling refrigerant R 134a .
Avoid contact with refrigerant and refrigerant fluid.
Follow safety instructions for HANDLING REFRIGERANT FLUID .
Refrigerant circuit is under high pressure!
Follow instructions for handling R 134a refrigerant. See 6450... SAFETY INSTRUCTIONS FOR HANDLING R134A REFRIGERANT or 6450... Instructions for handling refrigerant R 134a .
Avoid contact with refrigerant and refrigerant fluid.
Follow safety instructions for HANDLING REFRIGERANT FLUID .
IMPORTANT:
Risk of damage!
Restart engine only when air conditioning system has been correctly filled.
Necessary preliminary work:
- DRAWING OFF, EVACUATING AND FILLING THE AIR CONDITIONING SYSTEM are not included in the time value given for this job item
- Remove condenser for air conditioning system.
Remove protective cap (1).
Remove circlip (1) and pull out desiccant insert (2).
Installation note:
Replace sealing rings.
Use special tool 00 9 030 to mount sealing rings without damaging them.
After installation