Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 230 (Heating And Air Conditioning - Repair - Convertible (R57)) >> Air Conditioning, Leak Detection >> 64 52... Instructions for opening and replacing parts in refrigerant circuit >> Notes

64 52... Instructions for opening and replacing parts in refrigerant circuit: Notes

WARNING: This page is about a different variant/trim than selected.
WARNING:
IMPORTANT:
  • Always use new O-rings each time A/C connections are opened (refer to Electronic Parts Catalogue)

    They must not  be coated.

    Use special tool 00 9 030 to install sealing rings without damaging them.

  • Open the refrigerant circuit for as short of a period as possible.
  • Close all components and lines in the refrigerant circuit and return parts immediately  following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
  • If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 hours, the dryer insert for the air conditioning must be replaced.