12 14 524 Replacing Pulse Sensor On Exhaust Camshaft (N12)
WARNING: This page is about a different variant/trim than selected.
Necessary preliminary tasks:
- Switch off ignition
- Read out fault memory of DME control unit
- Check stored fault messages
Unlock plug (1) and remove.
Release screw and remove pulse sensor (2).
Installation:
Replace sealing ring and coat with anti-seize agent.
Tightening torque 13 62 4AZ
NOTE:
Delete fault memory.