13 62 618 Replacing the temperature sensor and charging pressure sensor (N14, N18)
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
Read and comply with notes on ESD PROTECTION (ELECTRO STATIC DISCHARGE)
.
Unlock connector (1) and remove.
Release screw and detach sensor (2) from charge air duct.
Installation note:
- Check sealing ring for damage, replace if necessary.
- When installing, coat sealing ring with suitable lubricant.
- Tightening torque 13 62 6AZ .
Check stored fault messages.
Delete fault memory.