64 53 515 Replacing desiccant insert for A/C system
WARNING: This page is about a different variant/trim than selected.
Special tools required: 00 9 030
WARNING:
Risk of injury!
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant oil.
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant oil.
- Follow safety instructions for HANDLING R134A REFRIGERANT .
- Follow safety instructions for HANDLING REFRIGERANT OIL .
IMPORTANT:
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Restart engine only when A/C system has been correctly filled.
Necessary preliminary tasks:
- DRAWING OFF, EVACUATING AND FILLING THE A/C SYSTEM are not included in the time value given for this work operation
- Remove CONDENSER FOR A/C SYSTEM
Remove protective cap (1).
Remove circlip (1) and pull out desiccant insert (2).
Installation note:
Replace sealing rings.
Use special tool 00 9 030 to mount sealing rings without damaging them.
After installation:
- Evacuate and fill A/C SYSTEM