Test precondition: 

Overheating protection not active. Voltage supply at independent parking heater O.K.

Coolant temperature < 40 °C

Vehicle tank adequately filled.

Instruction: 

Switch on independent parking heater via MID or on-board monitor.

Check clock pulse at metering pump 32 seconds after switching on independent parking heater.

PARK HEATING METERING PUMP FAULT DESCRIPTION

Question   Measure
Can clock pulse be heard at metering pump? No Fault 6.1 
Yes    
Disconnect fuel hose at independent parking heater and start independent heater several times if necessary until fuel emerges at heater connection. To measure delivery capacity, start independent parking heater twice and measure fuel quantity for 60 seconds at a time. Project metering quantity for 1 hour. Is a metering quantity of 650 ml/h +/- 10% reached? No Fault 6.2 
Yes    
The metering pump is O.K.