64 99... Fault 06 Park heating metering pump
WARNING: This page is about a different car, the 2003 BMW 530i, 2002 BMW 530i, and 2001 BMW 530i. However, it is still accessible from the selected car via links, so may be relevant.
Test Precondition:
Overheating protection not active. Voltage supply at independent parking heater O.K.
Coolant temperature less than 40°C
Vehicle tank adequately filled.
Instruction:
Switch on independent parking heater via MID or on-board monitor.
Check clock pulse at metering pump 32 seconds after switching on independent parking heater.
FAULT 06 PARK HEATING METERING PUMP TROUBLESHOOTING
| Question | Measure | |
|---|---|---|
| Can clock pulse be heard at metering pump? | No | Refer to Fault 6.1 |
| Yes | Disconnect fuel hose at independent parking heater and start independent heater several times if necessary until fuel emerges at heater connection. To measure delivery capacity, start independent parking heater twice and measure fuel quantity for 60 seconds at a time. Project metering quantity for 1 hour. |
|
| Is a metering quantity of 650 ml/h +/- 10% reached? | No | Refer to Fault 6.2 |
| Yes | The metering pump is O.K. | |