Test Groups WBMXV02.8M52 & WBMXV02.8Z35
WARNING: This page does not describe the selected car, but rather 14 other vehicles, including the 1998 BMW Z3, 1998 BMW M3, 1998 BMW M Roadster, 1998 BMW 750iL, and 1998 BMW 740iL. However, it is still accessible from the selected car via links, so may be relevant.
General Description - At cold start, secondary air pump and valve are switched on for their normal operating function. Secondary air delivered into exhaust gas is causing a lean mixture indicated by output voltage of oxygen sensor. Any time oxygen sensor indicates a lean mixture within maximum time for monitoring, a counter is incriminated by one count, up to a predetermined value. This fixed limit corresponds to minimum amount of secondary air (low-flow-limit-check).