LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 58 (Diagnostic Trouble Codes With Test Charts) >> Test Group Identification >> Evaporative System Monitoring >> Test Group WBMXV04.4M62

Test Group WBMXV04.4M62

WARNING: This page does not describe the selected car, but rather 14 other vehicles, including the 1998 BMW Z3, 1998 BMW M3, 1998 BMW M Roadster, 1998 BMW 750iL, and 1998 BMW 740iL. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: The evaporative system monitoring permits the detection of leaks in the evaporative emission control system with a diameter of 1 mm and up.
  1. Evaporative System Monitoring General Description -  By means of a Leak Detection Pump (LDP), a vacuum actuated pump located at the atmospheric connection of the charcoal canister, a pressure test of the evaporative system is performed in the following order:
    • During the FAST PULSE PHASE, the evaporative system is set under defined pressure. Pressure in the evaporative system after the Fast Pulse Phase may be higher or lower than the defined pressure depending on fuel level in the tank.
    • The NATURAL FREQUENCY PHASE that follows the FAST PULSE PHASE, is needed to adjust the pressure to is correct value.
    • During the final MEASUREMENT PHASE, the time between the pump strokes of the LDP is evaluated. In case of a time between pump strokes below a preset threshold a leak is assumed to be present.
    • During the pressure test, the purge valve needs to be shut. After the test canister purge is resumed and consequently the remaining pressure in the evaporative system is bled off.
    • To have the maximum purge capacity (or minimal loss of purge air due to leak detection) the test normally runs after engine cold start. However under certain circumstances the test may be preliminary aborted and started again later during engine run, provided all conditions for restart of the test are met.
  2. Evaporative System Monitoring Structure -  For EVAP system monitoring structure, refer to illustrations. See Fig 1-Fig 5 .
  3. Use Of Ambient Temperature Signal Provided By Vehicle Can Bus -  The LDP component is specified for defined temperature range. To prevent the component from being operated under unspecified conditions, ambient temperature is used as a condition for starting the monitoring sequence after cold start.

    The ambient temperature signal is checked for circuit continuity later in the driving cycle by means of the intake air temperature monitor (TAL_REF Monitor) as follows:

    • At the time of engine start the value of TAL_REF is initialized to the maximum possible value.
    • If a specified load and a specified vehicle speed is exceeded over a specific time the value of TAL_REF is updated with the value provided by the intake air temperature sensor. This is only done if the intake air temperature value is lower than the value that is already represented by TAL_REF. Thus TAL_REF always represents the minimum value of the intake air temperature sensor found during the conditions mentioned above.

    Using this technique the following sequences are possible:

    • The ambient temperature is within specified range and no leak is detected during the monitor sequence. In this case the system is considered to be without a leak and no fault code is stored.
    • The ambient temperature is within the specified range and a leak is detected during the monitoring sequence. After conditions for updating TAL_REF are met and TAL_REF is within specified range, a fault code is stored. In case TAL_REF is out of specified range, no fault code is stored.
    • The ambient temperature is out of specified range at the time of engine start. This leads to a preliminary abortion of the monitoring sequence, the monitoring sequence is then carried out as soon as all conditions for repetition after a preliminary abortion.

  4. Downhill Run Detection -  The LDP measures the difference between the internal tank pressure and the ambient pressure. In the case of a vehicle moving downhill the internal tank pressure remains constant whereas the ambient pressure increases. Consequently the pressure difference measured by the LDP decreases which may cause the detection of a leak that is not present (false alarm). To prevent this, a downhill run detection that compares the engine torque with a torque that is needed for driving the car on level terrain at a given speed, is implemented. Once a downhill run is detected the monitoring sequence is preliminary aborted.
  5. Typical Pressure Over Time -  For Pressure/Time graph, See Fig 6.

EVAP Purge System Flow Check Monitoring System -  Purge flow from the charcoal canister through the purge valve is monitored after the coolant temperature has reached a fixed minimum value. Diagnosis is started during regular purging.

Fig 1: EVAP System - Cold Start Conditions
G00222232Courtesy of BMW OF NORTH AMERICA, INC.
Fig 2: EVAP System - Conditions For Preliminary Abort
G00222233Courtesy of BMW OF NORTH AMERICA, INC.
Fig 3: EVAP System - Conditions For Repetition After Preliminary Abort
G00222234Courtesy of BMW OF NORTH AMERICA, INC.
Fig 4: EVAP System - Conditions For Final Abort Of Monitoring Sequence
G00222235Courtesy of BMW OF NORTH AMERICA, INC.
Fig 5: EVAP System - Monitoring Sequence
G00222236Courtesy of BMW OF NORTH AMERICA, INC.
Fig 6: Leak Detection Pressure Over Time Graph
G00222237Courtesy of BMW OF NORTH AMERICA, INC.