LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 4199 (Engine - Variable Valve Timing Control System (VANOS), Intake Plenum, Turbocharger, Water Pump, Thermostat, Coolant Lines, EGR Valve, EGR Cooler, Oxygen Sensors - Repair) >> Oxygen Sensors >> S63 Engine >> 11 78 543 Replacing right monitoring sensor (S63)

11 78 543 Replacing right monitoring sensor (S63)

WARNING: This page does not describe the selected car, but rather 50 other vehicles, including the 2016 BMW M5, 2016 BMW ActiveHybrid 5, 2016 BMW 550i xDrive, 2016 BMW 550i, and 2016 BMW 535i xDrive. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING: Risk of burning.

Only perform repair work after engine has cooled down.

Necessary preliminary tasks: 

Release retaining clip (1).

Remove heat shield (2) over oxygen sensor.

Detach oxygen sensor cable from retaining clips (3).

Graphic shows N63.

Fig 1: Identifying Wire Ring And Retaining Clip
G06178811Courtesy of BMW OF NORTH AMERICA, INC.

Release monitoring sensor (1) with special tool 11 7 020 .

Graphic shows N63.

Fig 2: Removing/Installing Monitoring Sensor Using Special Tool (11 7 020)
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

The threads of new oxygen control/monitoring sensors are already coated with NEVER-SEEZ COMPOUND .

If a lambda control/monitoring sensor is to be reused, apply a thin and even coating of Never-Seez Compound to the thread only.

The part of the lambda control/monitoring sensor which projects into the exhaust branch (sensor ceramics) must not  be cleaned and not  coated with lubricant.

Fasten monitoring sensor (1) with special tool 11 7 020 .

Tightening torque 11 78 1AZ .

Fig 3: Removing/Installing Monitoring Sensor Using Special Tool (11 7 020)
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

Check function of DME control unit.

Pay attention to cable routing of monitor sensor.