11 78 543 Replacing right monitoring sensor (S63)
Special tools required:
Only perform repair work after engine has cooled down.
Necessary preliminary tasks:
- Check function of DME control unit
- Remove DME CONTROL UNIT HOLDERS .
Release retaining clip (1).
Remove heat shield (2) over oxygen sensor.
Detach oxygen sensor cable from retaining clips (3).
Graphic N63.
Release monitoring sensor (1) with special tool 11 7 020 .
Graphic N63.
Installation note:
The threads of new oxygen control/monitoring sensors are already coated with NEVER-SEEZ COMPOUND .
If a lambda control/monitoring sensor is to be reused, apply a thin and even coating of Never-Seez Compound to the thread only.
The part of the lambda control/monitoring sensor which projects into the exhaust branch (sensor ceramics) must not be cleaned and not coated with lubricant.
Fasten monitoring sensor (1) with special tool 11 7 020 .
Tightening torque 11 78 1AZ .
Installation note:
Check function of DME control unit.
Pay attention to cable routing of monitor sensor.