LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 4162 (Intake Plenum, Turbocharger, Vacuum Pump, EGR Valve, Oxygen Sensors - Repair) >> Oxygen Sensors >> 11 78 540 Replacing left monitor sensor (N63)

11 78 540 Replacing left monitor sensor (N63)

WARNING: This page does not describe the selected car, but rather 27 other vehicles, including the 2017 BMW M6, 2017 BMW 650i xDrive, 2017 BMW 650i, 2017 BMW 640i xDrive, and 2017 BMW 640i. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING: Risk of burning! 
Only perform this work after engine has cooled down.

Necessary preliminary work: 

Release retaining clip (1).

Remove heat shield wire ring (2) over oxygen sensor.

Detach oxygen sensor cable from retaining clips (3).

Fig 1: Identifying Retaining Clip And Wire Ring
G06178812Courtesy of BMW OF NORTH AMERICA, INC.

Release monitoring sensor (1) with special tool 11 7 020 .

Fig 2: Releasing Monitoring Sensor
G06178835Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

The threads of new lambda control/monitoring sensors are already coated with NEVER-SEEZ COMPOUND .

If a lambda control/monitoring sensor is to be reused, apply a thin and even coating of Never-Seez Compound to the thread only.

The part of the lambda control/monitoring sensor which projects into the exhaust branch (sensor ceramics) must not  be cleaned and not  coated with lubricant.

Fasten monitoring sensor (1) with special tool 11 7 020 .

Tightening torque 11 78 1AZ .

Fig 3: Releasing Monitoring Sensor
G06178835Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

Check function of DME control unit.

Pay attention to cable routing of monitor sensor.