Diagnosis instructions
Control of the fuel presupply pressure is monitored by the DDE. Faults which arise as a result of control deviations are stored in the DDE fault memory.
Activation of the electric fuel pump is monitored by the fuel pump control module. Faults that occur are stored in the fault memory of the fuel pump control module.
When the DDE control unit is woken by a signal (wake-up), the electric fuel pump control unit is still not awake; the electric fuel pump is briefly activated for approx. 10 ms.
The electric fuel pump is not activated when terminal 15 is switched on. The electric fuel pump is activated only when the starter motor is actuated.
We can assume no liability for printing errors or inaccuracies in this document and reserve the right to introduce technical modifications at any time.