General information on power supply
Do not connect a trickle-charger to the cigarette lighter.
Power is fed to the cigarette lighter from the rear power distributor via a relay. This relay is deactivated when terminal 15 is switched off. That means that a trickle-charger connected to the cigarette lighter is separated from the battery. Only recharge the battery using the external-start support point. Only then can the energy fed into the vehicle be registered.
Intelligent battery sensor:
- Do not attach any additional connections to the negative terminal of the battery.
- Do not modify the earth cable in any way. The earth cable also serves to carry off heat.
- Do not create a connection between the IBS (intelligent battery sensor) and the sensor screw.
- Do not use force when disconnecting the terminal clamp from the battery terminal:
- Do not pull on the earth cable.
- Do not apply any tools under the IBS to lever off the terminal clamp.
- Do not use the IBS connections as a lever.
- Use a calibrated torque wrench with tightening torque set according to the Repair Instructions.
- Do not loosen or tighten the sensor screw (Torx screw).
- Prevent direct contact between the IBS and earth.
Change battery:
When the battery is replaced, the IBS (intelligent battery sensor) and the wires could be damaged beyond repair by mechanical stressing.
Please note the following when replacing the battery:
- Always proceed in accordance with the repair instructions.
- Avoid subjecting the integrated battery sensor to mechanical stress.
- If a battery with a different capacity is fitted, the CAS must be recoded. Run "Battery" retrofit with Progman.
- Erase any fault memory entry in the engine control unit relating to the battery replacement.
Micro-power module until 09/2005:
If consumers are cut off from the vehicle electrical system by the MPM, a fault will be registered in the fault memory. The following faults can be read off in the BMW diagnosis system:
- Fault at terminal 15
- Cutoff with information about switch-off conditions.
The information about the switch-off conditions is stored in the info memory used for storing additional information.
- Undervoltage
- Contact fault in relay contacts
Fault at terminal 15:
- If there is a different level at terminal 15, pin 14 and in the CAN message, the MPM will register a fault in the fault memory.
- The MPM cyclically monitors the relay contacts every 100 milliseconds (ms) from terminal 15 ON. If the relay contacts do not remain closed, despite the switch-on conditions being satisfied, an entry will be made in the fault memory.
Alternator:
Alternators manufactured by Bosch and by Valeo are installed on 5- and 6-Series vehicles.
- Air-cooled alternator models are used.
- The alternator model used depends on the engine installed and the vehicle's equipment specification.