Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 3761 (General Electrical System - Repair - F12) >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Socket housings, 5-pin, 8-pin, System MQS/MPQ

61 13... Socket housings, 5-pin, 8-pin, System MQS/MPQ

WARNING: This page does not describe the selected car, but rather 33 other vehicles, including the 2018 BMW M6, 2018 BMW 650i xDrive, 2018 BMW 650i, 2018 BMW 640i xDrive, and 2018 BMW 640i. However, it is still accessible from the selected car via links, so may be relevant.

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the connector housings:

Socket housing, 5-pin (Hybrid System MQS/MPQ) 

Raise fastener (1) over retaining lug (2) and pull off from contact carrier (3).

Fig 1: Pulling Retaining Lug From Contact Carrier
G08509510Courtesy of BMW OF NORTH AMERICA, INC.

Socket housing, 8-pin (MQS): 

Raise fastener (1) over retaining lug (2) and pull off from contact carrier (3).

Fig 2: Pulling Retaining Lug From Contact Carrier
G08509511Courtesy of BMW OF NORTH AMERICA, INC.

Hold down retaining hook (1) of contact and pull cable with contact as far as secondary lock (2).

Fig 3: Pulling Cable With Secondary Lock
G04727548Courtesy of BMW OF NORTH AMERICA, INC.

Hold down retaining hook in secondary lock (1) again and pull cable with contact (2) completely out of contact carrier (3).

Fig 4: Pulling Wire Out Of Contact Carrier
G04727549Courtesy of BMW OF NORTH AMERICA, INC.